System DELTA 30 - Modular furnishing system – Fume cupboard systems - experiment well in safety (for sure)
In order to fulfill the protective function, and thus the maintenance of occupational safety, the exhaust air volume flow is a decisive criterion. The retention of pollutants inside the fume cupboard and the resistance to external air currents that can interfere with the fume cupboard is highly dependent on the extraction volume. The further the sash is opened, the more the retention capacity of the fume cupboard is impaired.
Based on these considerations, DIN EN 14175 requires not only the static, but also the dynamic behaviour in the “robustness test” as proof. This simulates a disturbing movement in the room, in order to be able to evaluate the stability of the inflow and the retention potential of the fume cupboard. The DELTA 30 fume cupboards, with the extensive range of variants, meet the requirements of the DIN EN 14175 in in full with the best values. The exhaust system has optimized suction zones in the rear wall, which are easily disassembled for cleaning purposes, ensuring ideal air flow and ventilation. The interior of the fume cupboard is extensively usable. There are no disturbing built-in components. Optimal usage and maximum occupational safety – the evaluation factors for our fume cupboards.
- DELTAguard bench-mounted fume cupboard
- DELTAguard low ceiling bench-mounted fume cupboard
- DELTAguard Low-level fume cupboard
- DELTAguard Walk-in fume cupboard
- DELTAguard bench-mounted fume cupboard with service columns
- DELTAguard Filter fume cupboard
- DELTAguard Radionuclide fume cupboard
- DELTAguard High-performance fume cupboard
- DELTAcare fume cupboard
- DELTAguard Ex-fume cupboard
- Special equipment
- Hazardous substances wortstation
- DELTAbigbox
- Air Barrier Efficiency
- Weighing containment
- Enclosures
- Chemical disposal
- Disposal unit substructure
- Spot extraction
- DELTAguard PROTECT
- DELTAcontrol
Product advantages:
-
Hazardous substances workstation tested for air quality in accordance to EN 14175-3 (5.2.3, 5.4.4, 5.6.5)
-
Equipped with active air injection system
-
Optimized pollutant retention capacity with, at the same time, low exhaust air volume flows
-
Maximum interior space and freedom of movement combined with excellent transparency, thanks to slim sides, an open front and side glazing
-
Worktops depending to requirements
-
Flexible setup, even at existing workstations or height-adjustable desks
-
Front frame profile with flow-optimized front bead
-
Exhaust air system with optimized suction zones for, among other things, full-surface extraction above the work surface Maintenance-friendly thanks to large inspection panel, simple-to-disassemble installations
-
Electrical panels on both sides in the interior
-
High installation density possible, no overlapping of service outlet and stand/rod holder areas
-
Exhaust air function indicator intergrated into the pilaster at eye level
-
Interior lighting LED neutral white, 500 lx on the work surface
-
Optional: Base cabinet or hazardous materials cabinet